PRODUCTS Spellman > SL150KV
SL150kV Cable Connected Power Supply
기계적 구성
파워
출력 전압
Rack
1.2kW
150kV; positive, negative or reversible polarity
Spellman’s SL150kV rack mount high voltage power supply
is designed for scientific and industrial OEM applications
requiring 150kV at 1200 watts in a compact cable
connected standard sized rack. Models are available in
positive, negative or reversible polarity. The SL150kV is
fully arc and short circuit protected. Excellent regulation
specifications are provided along with outstanding stability
performance. The vacuum encapsulated high voltage
output section assures reliable corona free operation by
eliminating any concerns due to environmental factors.
TYPICAL APPLICATIONS
Electrostatics
HiPot Testing
Semiconductor Processing
Capacitor Charging
OPTIONS
200 200Vac Input Voltage
AOL Adjustable Overload Trip
APT Adjustable Power Trip
AT Arc Trip
BFP Blank Front Panel
CPC Constant Power Control
DPM4 4.5 Digit Panel Meters
EFR External Fault Relay
LL(X) Non-Standard HV Cable Length
(10 standard)
NAD No Arc Detect
NSS No Slow Start
RFR Remote Fault Reset
SS(X) Non-Standard Slow Start
(6 seconds standard)
• CABLE CONNECTED 150kV @ 1200W POWER SUPPLY
• REQUIRES ONLY 8.75˝ (5U) PANEL HEIGHT
• EXTENSIVE ANALOG INTERFACE
• ARC QUENCH/ARC COUNT/ARC TRIP
• COMPREHENSIVE DIGITAL FAULT DIAGNOSTICS
SPECIFICATIONS
Front Panel Controls:
Front Panel Controls Power ON/OFF switch, HV ON
Switch, HV OFF Switch with preset feature, 3.5 digit
backlight digital meters for display of output voltage
and output current,10 turn locking potentiometers with
counting dials for adjustment of both output voltage
and output current.
Front Panel Indicators:
HV ON High Voltage Inhibit
HV OFF Over Current
Voltage Control Mode Over Voltage
Current Control Mode Arc
Interlock Open Regulation Error
Interlock Closed Overtemperature
Input:
220Vac ±10%, 50/60 Hertz
Output Voltage:
0 to 150kV
Output Polarity:
Positive, negative or reversible specify at time of order
Output Current:
8mA
Output Power:
1200W
Voltage Regulation:
Load: 0.01% of rated voltage for a full load change
Line: ±0.01% of rated current over specified input
voltage range
Current Regulation:
Load: 0.01% of rated current ±100μA for full voltage change.
Line: ±0.01% of rated current over specified input
voltage range
Ripple:
0.1% peak to peak of maximum output
Temperature Coefficient:
100ppm/°C.
Stability:
100ppm/hr after a 2 hour warm up, for both voltage and current regulation