PRODUCTS Spellman > SLS
SLS Series 2kW Stack Power Supplies Rack Mount
기계적 구성
파워
출력 전압
Rack Mount
2kW
5 different maximum voltage ratings from 160-360kV
The SLS series of high voltage power supplies provide up
to 2000 watts of power with voltage outputs ranging from
160kV to 360kV. These power supplies utilize high frequency
resonant inverters with proprietary controls for reliable
operation in extreme environments. The high voltage multiplier
unit is built with a hybrid design of solid encapsulation
and air, thus reducing its overall size. Comprised of 20kV
interlocking wafers, the multiplier unit offers flexible building
blocks for many different output configurations.
TYPICAL APPLICATIONS
Ion Implantation Particle Accelerators
Electron Guns
SPECIFICATIONS
Input Voltage:
220Vac±10%, three phase, 50/60Hz. (200Vac±10% optional).
Output Voltage Range:
Models available from 160kV to 360kV and up
to 2000W. Each model is available with positive
or negative polarity outputs.
Voltage Regulation:
Better than 0.05% for specified line variations
and load variations.
Ripple:
0.1% p-p of maximum output voltage.
Remote Voltage Control:
0 to +10V for 0 to maximum voltage. Accuracy and
repeatability: 1% of maximum rating.
Remote Current Control:
0 to +10V for 0 to maximum voltage. Accuracy and
repeatability: 1% of maximum rating.
Voltage Monitor:
0 to 10V equivalent to rated voltage. Accuracy, 1% reading.
Current Monitor:
0 to 10V equivalent to rated current. Accuracy, 1% reading.
Stability:
0.05% per hour after 1/2 hour warm-up.
0.05% per 8 hours.
Slow Start:
Slow start times: 6 seconds standard.
Temperature Coefficient:
0.01% per degrees C.
Protection:
Overcurrent, Overvoltage, Arc protection, Overtemperature.
Arc Detect:
If 8 arcs occur in a 10 second, non-synchronous time window,
the supply reverts to the Power Down Mode with an ARC fault
displayed on the front panel default diagnostic display.
Environmental:
Temperature Range:
Operating: 0°C to 40°C
Storage: -20°C to 85°C
Humidity:
10% to 70%, non-condensing.
Dimensions:
Inverter Driver Chassis:
3.50”(2U)H x 19.0”W x 19.0”D (8.9cm x 48.3cm x 48.3cm)
Multiplier Unit:
Depends on model specified.
Distance from Stack to Driver:
2.5 meters ±0.1 meter maximum.
Signal Connector:
25 pin, male D connector, J3.
Metering:
Front panel, 3.5 digit, digital voltage and current meters.
Front Panel Controls:
Voltage and current are continuously adjustable by ten-turn
potentiometers with lockable counting dials, ON/OFF circuit
breaker/lamp, high voltage ON switch/indicator and high
voltage OFF switch/indicator.
Front Panel Status Indicators:
Voltage Control Mode Overcurrent
Current Control Mode Overvoltage
Interlock Open Arc
Interlock Closed Regulation Error
High Voltage Inhibit Overtemperature
Overpower (optional)
Regulatory Approvals:
Compliant to 2004/108/EC, the EMC Directive
and 2006/95/EC, the Low Voltage Directive.