LeCroy Oscilloscope
LeCroy
CHAUVIN ARNOUX(샤빈 아녹스)
IWATSU
Coherent Solutions
ODA(Power/ Load)
제전기 ( IONIZER )
Magna Power
NHR
APT
JENOPTIK
GWINSTEK
FLUKE
YOKOGAWA
AMETEK
NOISETECH
열충격시험기
Spellman
▶SL
▶205B
▶210
▶SL150KV
▶SLS
▶SA
▶ST
Spellman > SA
PRODUCTS Spellman > SA
SA Series 4kW-12kW Power Supply Rack Mount
기계적 구성
파워
출력 전압
Rack Mount
4kW, 8kW, 12kW
13 different maximum voltage ratings from 1-70kV
SA power supplies are available in 13 models with voltage
outputs ranging from 1kV to 70kV. Similar to the SR power
supplies, they incorporate series resonant inverter technology
with a patented control circuit. This enables the supplies
to operate without damage or interruption in rugged
environments that frequently pose threats to conventional
high voltage power supplies. In addition, the SA Series
protect your load from excessive peak current when an
arcover condition is sensed. Parallel operation options to
increase power and current capabilities are available for
SA models with power outputs of 8kW, 12kW and higher.
TYPICAL APPLICATIONS
Sputtering CW Lasers
Analytical X-ray Ion Implantation
Electron Beam Systems Capacitor Charging
Radar Modulators
OPTIONS
200-1P 200Vac Single Phase Input
200-3P 200Vac Three Phase Input
220-1P 220Vac Single Phase Input
AOL Adjustable Overload Trip
FG Floating Ground
CPC Constant Power Control
APT Adjustable Power Trip
RMI Remote Mode Indicators
ROA Remote Overvoltage Adjust
NSS No Slow Start
SS(x) Nonstandard Slow Start
SL Mounting Slides
BFP Blank Front Panel
SPECIFICATIONS
Input:
208Vac±10%, 50 or 60Hz, three phase.
Output:
13 models from 1kV to 70kV. Each model is available
with positive, negative or reversible polarity outputs.
Output Controls:
Voltage and current are continuously adjustable
over entire range via ten-turn potentiometers with
lockable counting dials.
Voltage Regulation:
Load: 0.005% of full voltage +500mV for full load change.
Line: ±0.005%of full voltage +500mV over specified input range.
Current Regulation:
Load: 0.05% of full current ±100μA for any voltage change.
Line: ±0.05% of full current over specified input range.
Ripple:
0.1% +1Vrms for three phase models only.
0.3% +1Vrms for single phase models only.
Temperature Coefficient:
100ppm/°C. Higher Stability (50ppm/°C)
available on special order.
Stability:
0.01%hr. after 1/2 hour warm-up, 0.02% per 8 hrs. (typical).
Metering:
Digital voltage and current meters, 1% accuracy.
System Status Display:
“Dead Front” type indicators provide status of up to 14
system operations including voltage and current regulation,
fault conditions and circuit control.
Output Cable:
10 ft. (3.05m) shielded high voltage cable,
removable at rear panel.
Dimensions:
51/4”H (3U) x 19”W x 22”D rack mount.
(13.3cm x 48.3cm x 55.9cm)
Regulatory Approvals:
Compliant to 2004/108/EC, the EMC Directive
and 2006/95/EC, the Low Voltage Directive