[ 제품 문의하기 / Request ]
제품 가격 및 정보에 대하여 문의가 필요하신 분은 아래 버튼을 클릭하여 주세요.
For inquiries about product prices and information, please click the button below.

Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 1400 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
The CP030B and CP031A provide a high sensitivity of 1mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
Teledyne LeCroy current probes under 1000A are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. The ProBus connection also allows all of the current probes and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope’s user interface.
The DCS025 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030B, CP031, and CP031A are compatible with the DCS025.
| Model | Max Continuous Input Current | Max Peak Current | Bandwidth | Minimum Sensitivity | Coupling | Max Conductor Size (diameter) | Interface |
| CP030B | 30A | 50A | 50 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| CP031 | 30A | 50A | 100 MHZ | 10mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| CP031A | 30A | 50A | 100 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| AP015 | 30A | 50 A | 50 MHz | 10 mA/div | AC, DC, GND | 5 mm | Probus, 1MΩ only |
| CP150B | 150 A | 500 A | 10 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only |
| CP500 | 500 A | 700 A | 2 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only |
| CP1000 | 1000 A | 1400 A | 1.5 MHz | 100 mA/div | AC, DC, GND | 33 mm | Probus, 1MΩ only |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.

Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 1400 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
The CP030B and CP031A provide a high sensitivity of 1mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
Teledyne LeCroy current probes under 1000A are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. The ProBus connection also allows all of the current probes and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope’s user interface.
The DCS025 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030B, CP031, and CP031A are compatible with the DCS025.
| Model | Max Continuous Input Current | Max Peak Current | Bandwidth | Minimum Sensitivity | Coupling | Max Conductor Size (diameter) | Interface |
| CP030B | 30A | 50A | 50 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| CP031 | 30A | 50A | 100 MHZ | 10mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| CP031A | 30A | 50A | 100 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only |
| AP015 | 30A | 50 A | 50 MHz | 10 mA/div | AC, DC, GND | 5 mm | Probus, 1MΩ only |
| CP150B | 150 A | 500 A | 10 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only |
| CP500 | 500 A | 700 A | 2 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only |
| CP1000 | 1000 A | 1400 A | 1.5 MHz | 100 mA/div | AC, DC, GND | 33 mm | Probus, 1MΩ only |
배송안내
배송 지역 | 대한민국 전지역
배송비 | 2,500원 (50,000원 이상 결제시 무료배송)
배송기간 | 주말 공휴일 제외 2~5일
- 모든 배송은 택배사 사정으로 지연될 수 있습니다.
교환 및 반품 안내
- 고객 변심으로 인한 교환/반품은 상품 수령 후 14일 이내 가능합니다.
- 고객 귀책 사유로 인한 반품의 경우 왕복 택배비는 고객 부담입니다.
- 반품접수 기한이 지난 경우, 제품 및 패키지 훼손, 사용 흔적이 있는 제품은 교환/반품이 불가합니다.
[ 연관상품 ]