CA 6524

Designed for test and maintenance teams working in industrial or administrative buildings, the Qualistar+ C.A 8336 can be used to obtain a snapshot of the main features characterizing the quality of the electrical network.. This analyser’s functions make it the ideal instrument for preventive or corrective maintenance. It can also be used to perform a complete energy survey of an installation.

Description

Description

Highlights

1 kV Insulation and Continuity Tester
Industrial maintenance
200 GΩ
Test voltage: 50-100-250-500-1 000 V
Manual / Lock / Duration modes, PI / DAR ratios
Alarms, ∆REL

Description

Ergonomics:The new C.A 652x & C.A 653x insulation testers are compact, lightweight and simple to use, offering greater comfort for users:

– Casing designed with 600V CAT IV safety and IP54 / IK04 protection for a comfortable grip in total safety with easy access to the TEST button, even when the user is wearing safety gloves

–  Magnetic stand for fixing the product on a metal surface so that users have their hands free when measuring and reading the result

–  Wide backlit screen with double digital display and logarithmic bargraphsecondary display showing the actual test voltage, the test current and the timer value, in addition to the value measured

–  Remote control with torch for error-free identification of the points of measurement, even in environments with poor lighting

Insulation tests:

This new range is equipped with various insulation test voltages ranging from 10 V to 1 kV. The dynamic range for insulation measurement extends up to 200 GΩ, remaining compliant with the IEC 61557 standard up to 2 GΩ.

In addition to the manual mode, there are also new insulation test modes such as Lock modeTimer mode and calculation of the PI & DARratios.

Continuity tests:

The continuity test function, which complies with the IEC 61557 standard (200 mA current), is enhanced on certain models with a 20 mA test current, with the advantage of prolonging battery life in normal use. This function is equipped with activefuselessprotection if a voltage is present.

Measurement adaptability:

On most of the models in the C.A 652X & C.A 653x range, you can activate an alarm threshold, choosing between 2 fixed thresholds and 1 customizable threshold for each measurement.

Furthermore, the ΔREL function can be used to display the measurements which differ from a reference measurement. The display shows the value of the variation and the percentage in relation to the reference.

Other functions:

DMM functions are available with measurement of  voltage up to 700 Vfrequency up to 800 Hzresistance up to 999 kΩ and capacitance up to 10 µF.

Easy operation:

Analysis of the measurements is facilitated by storage of 300 measurements on the instrument. The memory capacity is extended to 1,300 locations for the versions with Bluetooth® communication. The Megohmmeter Transfer (MEG) software module, delivered as standard with the communicating versions, allows remote test activation with real-time graphical display and transfer of the stored measurements onto a PC. The values are then displayed by type of measurement.

The DataView® software suite (option) generates customized measurement reports which may include the location of the site and the contact details of the operator.

Specifications:

INSULATION: 50-100-250-500-1000 V test voltage

Measurement range: 200 GΩ

Test mode: Manual, Lock, Timer, PI, DAR

Continuity: 200mA / 20mA measurement current

Voltage measurement: 700 V

Frequency measurement: 15.3 – 800 Hz

Resistance measurement: 0 – 1,000 kΩ

Double display + logarithmic bargraph

Storage: 300 measurements

Magnetic mounting elements

Alarms

Powered by 6 x LR6 / AA batteries

Dimensions: 211 x 108 x 60 mm

Weight: 850 g

IP54 , safety category: 600 V CAT IV